1. Ozone occurs when oxygen radicals combine with oxygen molecules.             a. True             b. False 2. The most powerful oxidizer that can safely be …

1. Ozone occurs when oxygen radicals combine with oxygen molecules.

            a. True

            b. False

2. The most powerful oxidizer that can safely be applied in water treatment is:

            a. hydrogen peroxide (H2O2)

            b. potassium permanganate (KMnO4)

            c. ozone (O3)

            d. free chlorine (Cl2)

3. Combining ozone with hydrogen peroxide (or ultraviolet light) creates oxidation potential that is:

            a. equivalent to the weighted average at the combined ozone and the hydrogen peroxide (or UV)

            b. greater than either the ozone or hydrogen peroxide (or UV) separately

            c. subdued below that of the ozone alone

4. Ozone in drinking water can be used to inactivate protozoan cysts and oocysts, such as Giardia and Cryptosporidium.

            a. True

            b. False

5. Ozone will react with and destroy the following volatile organic chemical (VOC) compound(s):

           a. trichloroethylene

           b. benzene

           c. carbon tetrachloride

6. The need to dry the feed gas to -60° C dew point is most critical for:

            a.  ultraviolet ozone generators

            b. corona discharge ozone generators

            c. both a and b

7. Concentrations of ozone produced in air and that can be transferred to water are approximately __________ times greater using corona discharge generators than ultraviolet ozone generators:

            a. 2-5

            b. 5-10

            c. 10-100

8. Ozone compatible materials include:

            a. synthetic rubbers

            b. rigid copper pipe

            c. galvanized metal pipe

            d. PVDF (Kynar)

9. Ozone can be used to remove hydrogen sulfide from water.

            a. True

            b. False

10. Ozonated waters containing organic compounds such as tannins and synthetic organic chemicals (SOCs) can result in __________ microbiological regrowths downstream of the ozonation process. 

            a. increased

            b. lower

Sponsored Recommendations

NFPA 70B a Step-by-Step Guide to Compliance

NFPA 70B: A Step-by-Step Guide to Compliance

How digital twins drive more environmentally conscious medium- and low-voltage equipment design

Medium- and low voltage equipment specifiers can adopt digital twin technology to adopt a circular economy approach for sustainable, low-carbon equipment design.

MV equipment sustainability depends on environmentally conscious design values

Medium- and low voltage equipment manufacturers can prepare for environmental regulations now by using innovative MV switchgear design that eliminates SF6 use.

Social Distancing from your electrical equipment?

Using digital tools and apps for nearby monitoring and control increases safety and reduces arc flash hazards since electrical equipment can be operated from a safer distance....