Portable monitoring
ATI's new portable Series PQ45 answers the need for a field-deployable monitor capable of measuring and recording water quality data in a variety of operating environments. It is ideal for short-term recording of specific parameters such as Free Chlorine in potable water. The systems are available for monitoring various components in water. The available measurements are dissolved oxygen, free & combined residual chlorine, dissolved ozone, residual chlorine dioxide, conductivity and pH or ORP. Each PQ45 system is supplied ready to use for the parameter specified. If systems are to be used for free or combined chlorine, dissolved ozone, or chlorine dioxide, a second measurement of pH can be added to the system.
Analytical Technology Inc.
Collegeville, PA
www.analyticaltechnology.com
Circle No. 240 on Reader Service Card
UV disinfection
The Barrier® Sunlight V series of UV disinfection systems from Siemens Water Technologies are compact, vertically oriented modules that offer unlimited application flexibility with reduced operation and maintenance costs. The staggered lamp array offers built-in redundancy, ensuring maximum transmittance of UV radiation to the wastewater to help achieve disinfection requirements. The design also simplifies routine maintenance. Electronic ballasts and automatic flow-pacing optimize energy consumption and extend lamp life which reduce operating costs.
Siemens Water Technologies
Vineland, NJ
Tel: 800-525-0658
Web: www.water.siemens.com
Circle No. 241 on Reader Service Card
Chlorine monitoring
The Rosemount Analytical Model TCL from Emerson Process Management is a reagent-based system for measuring true total chlorine in water. Ideal applications are the analysis of drinking water and reclaimed wastewater. The reagent, potassium iodide dissolved in white vinegar, is inexpensive and needs replacing only every other month. Sample flow requirement is less than six gallons per day, a real advantage in places where drainage is limited or water is scarce and can't be wasted.
Emerson Process Management, Rosemount Analytical
Irvine, CA
Tel: 800-854-8257
Web: www.rosemountanalytical.com
Circle No. 242 on Reader Service Card
UV systems
Ozonia North America's new Aquaray® 36 UV system uses medium pressure, high output UV lamps, in a flow through UV reactor configuration that can be installed directly in a pipeline, resulting in a low head loss and a small system footprint. Depending on water quality, each system can disinfect flows in the 50 mgd range.
Ozonia North America
Elmwood Park, NJ
Tel: 210-794-3100
Web: www.degremont-technologies.com
Circle No. 243 on Reader Service Card
Disinfection products
Grundfos' Disinfection provides a diverse assortment of products ranging from bleach feed skids and chlorine gas feed to onsite bleach and chlorine dioxide generation. The VACCUPERM chlorine disinfection systems measure and control chlorine gas dosing. The full vacuum system provides safe and reliable feed. The SELCOPERM electrolysis systems generate chlorine directly on site using only salt and electricity.
Grundfos Disinfection
Olathe, KS
Tel: 913-227-3400
Web: www.grundfos.us/industry
Circle No. 244 on Reader Service Card
Ozone diffusers
Diffused Gas Technologies offers an updated line of ceramic gas diffusers for the interfacing of ozone gas with potable water, wastewater, and groundwater remediation applications. The ceramic diffusers are offered in two configurations. The model FBS Series diffusers are vertical format units constructed of corrosion resistant #316 stainless steel and aluminum oxide ceramic matrix. The FBT Series ceramic diffuser is a horizontal format tubular device.
Diffused Gas Technologies Inc.
Lebanon, OH
Tel: 513-934-4418
Web: www.diffusedgas.com
Circle No. 245 on Reader Service Card
UV disinfection
As more municipalities adopt wastewater reuse policies and practices, wastewater treatment plants are required to treat effluent to an even higher quality. In response, TrojanUV introduced the TrojanUVFit™ - an energy-efficient, closed-vessel UV reactor designed to disinfect filtered effluent without breaking head in the treatment process. This compact reactor is available in multiple configurations to treat a wide range of flow rates.
Trojan Technologies
London, Ontario Tel: 888-220-6118 Web: www.trojanuv.com
Circle No. 246 on Reader Service Card
Gas leak detector
Eagle Microsystems has introduced its next generation of gas leak detectors for chlorine, sulfur dioxide, ammonia, and ozone for use in water and wastewater applications. The Model GD4000 Alarm Indicator Unit is capable of supporting up to four electrochemical gas sensors for the same or different gases simultaneously.
Eagle Microsystems, Inc.
Pottstown, PA
Tel: 800-780-8636
Web: www.eaglemicrosystems.com
Circle No. 247 on Reader Service Card
On-Site hypochlorite
MIOX's new Vault™ small series on-site generator is designed to be self-cleaning and virtually maintenance free. With its self-adjusting flow control, the system uses salt and power to generate a dilute chlorine-based solution. The system features an easy-to-upgrade cell to convert between sodium hypochlorite and advanced mixed oxidant with expandable capacity.
MIOX Corp.
Albuquerque, NM
Tel: 888-646-9426
Web: www.miox.com
Circle No. 248 on Reader Service Card
Gas flow control valve
The new Capital Controls® Chloromatic™ 3000 Intelligent Gas Flow Control Valve automatically controls chemical feed in water or wastewater applications. The wall-mounted, integrated, microprocessor-based controller with control valve responds to multiple process signals from a water flow transmitter or chlorine residual analyzer, eliminating the need for continuous operator monitoring.
Severn Trent Services
Colmar, PA
Tel: 215-997-4000
Web: www.severntrentservices.com
Circle No. 249 on Reader Service Card
Peracetic acid
Proxitane® WW-12 peracetic acid, available from Solvay Chemicals, is an EPA-registered alternative to conventional wastewater disinfection. The chemical is biodegradable, leaving no halogenated residues. It is fast acting and cost effective, with low dosage and low capital. It is convenient, with one-step, liquid treatment requiring no neutralization step. And it is safe and stable, with a long shelf life for intermittent applications.
Solvay Chemicals US
Houston, TX
Tel: 713-525-6800 Web: www.solvaychemicals.us
Circle No. 250 on Reader Service Card
Chemical scales
The Chlor-Scale 150® from Force Flow provides a simple and reliable way to monitor the amount of chlorine or ammonia used and the amount remaining in the cylinder. The solid PVC scale platform, with a 5-year warranty, is corrosion resistant. The scale is available as an electronic system with the Wizard 4000® or SOLO G2®, or as a hydraulic system with the SOLO XT® or Century® dial.
Force Flow Equipment
Concord, CA
Tel: 800-893-6723
Web: www.forceflow.com
Circle No. 251 on Reader Service Card
Chlorine monitoring
The Hach CL17 uses DPD colorimetry, the only on-line, continuous measuring technology that is approved by the EPA for reporting chlorine. The device provides unattended operation for up to 30 days and has maintenance that is predictable and requires no special tools. It leverages the company's proprietary DPD formulation that minimizes interferences due to water hardness or minerals and delivers results independent of sample pH, temperature, chlorine concentration, pressure and flow.
Hach Co.
Loveland, CO Tel: 800-227-4224 Web: www.hach.com
Circle No. 252 on Reader Service Card
Chlorine analyzer
Hanna Instruments has introduced the PCA 320 in-line chlorine analyzer, the only DPD based chlorine system that includes pH and temp. That means a significant cost savings because there is no longer a need for a separate pH controller. The analyzer comes with two 4-20 mA outputs, so both critical parameters can hook directly to SCADA systems.
Hanna Instruments
Tel: 800-426-6287
Web: www.hannainst.com
Circle No. 253 on Reader Service Card
On-site disinfection
Severn Trent Services has released a technical brochure on the ClorTec® line of on-site sodium hypochlorite generating systems, highlighting the ways the systems can reduce a customers' carbon footprint and salt consumption by as much as 20 percent. The new brochure details the advantages of the on-site generation process and focuses on the environmental benefits offered through the use of the ClorTec system.
Severn Trent Services
Fort Washington, PA
Circle No. 254 on Reader Service Card
Ozone injection
Mazzei's GDT™ Process is used to inject ozone into treatment systems. It supports small- and large-scale treatment applications through innovative pressurized side stream and/or full flow contacting. In wastewater treatment, disinfection with ozone to inactivate bacteria prior to discharging the effluent has significant advantages: rapidly inactivating fecal coliforms, eliminating chlorine residual and increasing dissolved oxygen.
Mazzei Injector Co.
Bakersfield, CA
Tel: 661-363-6500
Web: www.mazzei.net
Circle No. 255 on Reader Service Card
Gas chlorinator
The Regal™ Gas Chlorinator is used all over the world to disinfect and purify municipal drinking water and wastewater, industrial process wastewater and more. It provides a consistent chlorine residual, eliminating a lot of guesswork. The all-vacuum system virtually eliminates the possibility of gas leaks. It is directly mounted with the strongest yoke in the industry, has a tough and resilient diaphragm and is made with corrosion-resistant materials.
Chlorinators Inc.
Stuart, FL
Tel: 772-288-4854 Web: www.regalchlorinators.com
Circle No. 256 on Reader Service Card
UV disinfection
Aquionics offers the OpenLine series of open channel UV treatment systems, which are designed to treat secondary wastewater flows over a wide range of flows and UV transmittances. The series employs a new type of low pressure, high output (LPHO) amalgam lamp that possesses a more stable output over its operating life.
Aquionics
Erlanger, KY
Web: www.aquionics.com
Tel: 859-341-0710
Web: www.aquionics.com
Circle No. 258 on Reader Service Card
Gas flow meter
The GF90 Mass Flow Meter from Fluid Components International provides gas measurement in applications such as chlorinated water disinfection systems, with less maintenance, and lower installation and operating costs. The meter is inserted in chlorine gas process piping, and its 4-20 mA output wired to the input/output (I/O) modules in the automation system.
Fluid Components International
San Marcos, CA
Tel: 800-854-1993
Web: www.fluidcomponents.com
Circle No. 259 on Reader Service Card
Bleach test kit
Sodium hypochlorite is not chemically stable and decomposes while in transit and storage. It degrades even faster when exposed to heat and light. Utilities that buy bleach in bulk can use Taylor Technologies' Chlorine Bleach Drop Test (K-1579) at the time of delivery to verify the available chlorine content meets the labeled concentration.
Taylor Technologies Inc.
Sparks, MD
Tel: 800-837-8548
Web: www.taylortechnologies.com
Circle No. 260 on Reader Service Card
Hypochlorite injection system
Fluid Metering has introduced its new Chloritrol™ valveless metering system for injection of sodium and calcium hypochlorite for purification of municipal drinking water. The system has a valveless duplex pump design. The first pump head is high pressure and injects the sodium hypochlorite directly into the water main. The second pump head functions to remove out-gas bubbles from the inlet side of the high-pressure pump head. The system is smaller and uses less energy than conventional injection pumps.
Fluid Metering Inc.
Syosset, NY
Tel: 800-223-3388 Web: www.fmipump.com